Every question on frcsent.app is an original single best answer item, written to the structure of the JCIE sample questions, mapped to a module of the Otolaryngology syllabus blueprint and referenced to current UK guidance or a standard text. Content is drafted with AI tools under a defined house style and checked against its cited reference. No ENT surgeon has reviewed the content yet: specialist review is pending, and this page will say when and where it has happened.

6 min read Updated 14 November 2026Editorial standards

Our standard for a question

We write to the structure of the JCIE’s published Otolaryngology sample questions. In practice that means:

  • A lean clinical vignette. Every clause in the stem either sets the scene or changes the answer. Anatomy, audiology and statistics are asked through a patient, an operation or a decision, not as a bare fact.
  • Five same-category options. Five operations, five investigations, five drugs, five hearing devices, five next steps, so the answer cannot be found by eliminating options of the wrong type.
  • One defensible best answer. Several options may be plausible; exactly one is best for this patient under current UK practice, and the explanation says why the others are not.
  • A clear lead-in. Which is the most likely diagnosis, which structure is at risk, which is the most appropriate next step.
  • Syllabus mapping. Every question is mapped to a topic and subtopic of our map of the JCIE syllabus blueprint, so you can see coverage and performance by domain on the syllabus.

Difficulty is calibrated to the standard the examination is set at: a day-one consultant in the generality of otolaryngology, head and neck surgery. A question is hard because its best options are close — separated by a threshold, an audiometric detail, a contraindication or one finding in the stem — not because the stem is obscure.

Exhibits drawn from data

We do not use images we do not hold the rights to. Where a question needs an audiogram or a tympanogram, the question writer chooses the data — the thresholds at each frequency, masking, the peak pressure, admittance and ear-canal volume — and our renderer draws the chart. Audiograms follow the British Society of Audiology recommended procedure: separate right and left charts, frequency against hearing level at 20 dB to an octave, O and X for air conduction, Δ for unmasked and [ ] for masked bone conduction. Tympanograms report the numbers the BSA asks for, and we never print a classification on the chart. The automated checks reject impossible data, such as bone conduction worse than air conduction. Every exhibit has a text description for screen readers, works on a phone and opens full screen to zoom. Other findings — otoscopy, endoscopy, imaging, histology — are described in words.

Explanations

Each explanation says what the question is testing, justifies the best answer, explains why each distractor is wrong or less good for this patient, and ends with a reference. Where the question turns on a number — a threshold in a guideline, a grade, a timing — the explanation gives it and says where it comes from.

How the bank is proportioned

The JCIE publishes a syllabus blueprint for Otolaryngology but no question weightings. The bank is therefore mapped to the blueprint, not weighted to it. The number of questions we hold on each domain is an editorial judgement of how broad that domain is, informed by the spread of the JCIE’s 50 sample questions, and we do not present it as the proportion of the real paper.

Where the facts come from

Explanations are referenced to current UK guidance and standard texts, including:

  • NICE guidelines and the NICE Clinical Knowledge Summaries, including those on hearing loss in adults, otitis media with effusion, head and neck cancer, thyroid disease and suspected cancer referral
  • SIGN guidance, including the management of sore throat and the indications for tonsillectomy
  • ENT UK and its specialty associations, and the UK national multidisciplinary guidelines for head and neck cancer
  • BAHNO, the British Thyroid Association and the British Association of Endocrine and Thyroid Surgeons
  • The British Society of Audiology recommended procedures for audiometry and tympanometry
  • Scott-Brown’s Otorhinolaryngology Head and Neck Surgery for the principles behind the guidance
  • International guidance where UK practice follows it (EPOS for rhinosinusitis, TNM for staging)
  • Landmark trials, named by author, journal and year, where a recommendation rests on one

We write to the current version of UK guidance, because the examination is set to present-day UK practice. Where a textbook and current UK guidance differ, the guidance is the answer; where two standard texts differ, the explanation says so and names the one we follow.

Review and sign-off

Questions are drafted and typeset to our house style, then checked by the editorial team against the reference each explanation cites: the best answer, the discriminator and any figures quoted must match current UK guidance or the named text.

The free sample on free questions is drawn from the same bank and held to the same standard, so it is representative of what you get when you subscribe.

How we use AI

We use AI tools openly, for two jobs: drafting questions, explanations and exhibit data to a written house style, and keeping a bank of this size consistent in format, terminology and referencing across nine domains. AI is never the final word. It does not decide what is correct; the cited reference and the human checker do.

AI drafts can contain errors, as can human ones. That is why every item is checked against its reference, why the review status above is published rather than assumed, and why the correction process below exists.

Reporting an error

If you think a question is wrong, out of date or ambiguous, flag it in the app so you can find it again and tell us through the contact form, with enough detail to identify the question and your reasoning, ideally with a reference. Every report is triaged. Where an error is confirmed, the question is corrected or retired and the change is logged.

Spelling and typography

Questions and explanations use UK English spelling and UK drug names. Ranges take an en-dash (2–3 weeks), dimensions take a multiplication sign (3 × 2 cm), and units are written the way UK results are reported: dB HL for hearing thresholds, daPa for pressure, ml for admittance and ear-canal volume. None of this changes an answer, but consistency means you are never slowed by the page.

What we will not claim

  • No guaranteed pass. No question bank can guarantee a result, and we will not suggest otherwise.
  • No pass-mark percentages. We do not quote a pass mark for Section 1.
  • No official weightings. The JCIE publishes none, so we do not say the bank is weighted to the examination.
  • No invented exam frequencies. We do not say that a topic ‘comes up every year’.
  • No recalled or official questions. Our questions are original. We are not affiliated with or endorsed by the JCIE, the ICBSE, the Royal Colleges of Surgeons or ENT UK.
  • No review we have not had. Specialist review is pending; we do not claim consultant or named-reviewer sign-off that has not taken place.
  • No fake reviews. We do not publish invented testimonials, ratings or pass rates.

Frequently asked questions

Are your questions recalled from the real exam?

No. They are original single best answer questions written to the structure of the JCIE sample questions. frcsent.app is independent: it is not affiliated with or endorsed by the JCIE, the ICBSE, the Royal Colleges of Surgeons or ENT UK.

Who reviews the questions?

The editorial team checks every question against the reference its explanation cites. No ENT surgeon has reviewed the content yet; specialist review is pending, and we will publish which sections have had it rather than claiming sign-off.

Where do the audiograms come from?

They are drawn by our own software from the data in each question, in British Society of Audiology format. No real patient's results and no copyrighted charts are used.

Do you use AI to write questions?

Yes, for drafting and consistency under a defined house style. AI is never the final word: the cited reference and a human checker decide what is correct.

Is the bank weighted to the exam?

No. The JCIE publishes no question weightings for FRCS (ORL-HNS) Section 1. The bank is mapped to the JCIE syllabus blueprint, and the number of questions on each domain is our own editorial judgement of its breadth.

What level are the questions pitched at?

The standard the examination is set at: a day-one consultant in the generality of otolaryngology. Questions are applied — a patient, a finding, a decision — rather than bare recall.

How do I report an error in a question?

Flag the question in the app and use the contact form, ideally with a reference. Reports are triaged, and where an error is confirmed the question is corrected or retired and the change logged.

Can I rely on this content in clinical practice?

No. It is written for examination revision, not clinical advice. Follow current national and local guidance when caring for patients.

References

  1. Joint Committee on Intercollegiate Examinations. Otolaryngology examination page
  2. JCIE. Intercollegiate Specialty Examination in Otolaryngology Syllabus Blueprint 2023 (V2.0)
  3. JCIE. Otolaryngology 50 sample questions with reasoning
  4. British Society of Audiology. Recommended procedure: pure-tone air-conduction and bone-conduction threshold audiometry with and without masking. 2018.
  5. British Society of Audiology. Recommended procedure: tympanometry and acoustic reflex thresholds. 2024 (minor revisions to November 2026).

Written for revision in the FRCS (ORL-HNS) style under our editorial standards. It is not clinical advice: always confirm against current guidance. Spotted an error? Tell us.

Judge the questions for yourself

The free sample is drawn from the same bank, written and checked to the same standard.